Sticking doors… and a leak upstairs!

Nov 1
2 min read

At first, the toilet door would no longer close properly. Over time, other doors in the apartment began to stick too. The door frames had swollen, but the cause wasn’t obvious. That’s when the client contacted us.


During our visit, we inspected the hallway with a thermal imaging camera. Several cooler areas showed up around the door frames. Near the toilet, we also spotted a thermal anomaly where the wall met the ceiling. These clues led us to continue our investigation in the apartment upstairs.


First-floor apartment


The second-floor apartment had a very similar layout to the one below: the toilet was in the same position, on the left as you entered. We continued our inspection there to find the source of the thermal anomalies observed on the first floor.


The toilet room was fully tiled, but an access hatch provided access to the valves and pipework. While checking this area, we found a leaking pipe.


Water had seeped into the apartment below and spread beneath the floor coverings. It had then worked its way up into the bases of several door frames in the entrance hall, causing the wood to swell. The damage therefore extended beyond the area directly beneath the leak.


This explained what the client had noticed over time: first, the toilet door would no longer close properly, and then other doors had started to stick. All these signs had the same cause, in the apartment upstairs.


Second-floor apartment


The leak was difficult to spot with the naked eye. Thermal imaging provided clues that a visual inspection alone could not reveal. It helped us identify the areas to investigate and directed our search to the apartment upstairs.


That’s the value of this method: inspecting without damaging finishes and reducing the need to open up walls or floors during the investigation. If an opening is then needed for repairs, it can be more precisely located.


The camera does not see water directly through materials. It reveals surface temperature differences which, combined with checks on site, help us trace the source of the problem.


In this case, it all started with a door that would no longer close. The cause was one floor above.

 
 